Re: [linux-audio-user] SysExxer and Clavia Nord Stage

From: Christoph Eckert <ce@email-addr-hidden>
Date: Mon Apr 17 2006 - 20:59:36 EEST

Hi Markus,

> I want to send a sysex dump to my Clavia Nord Stage, but I get some
> strange messages: First "Data successfully sent", then "Some error
> occured while writing to ". The Nord Stage hasn't received anything.

this can happen if there is a problem with the ALSA OSS emulation;
Sysexxer CVS can work on top of ALSA, but still requires an OSS device.

> I use the latest CVS version 0.8 of Sysexxer. The MIDI connections
> are set through ALSA. Sending sysex from the Nord Stage to Sysexxer
> works perfectly.

Great. Unfortunately, the development of Sysexxer is discontinued.

> According to the manual the Nord Stage is able to receive sysex data
> at any time. There is no special mode or special setting to configure
> the way it receives the data.

Sysexxer will never complain if any device didn't accept data. The data
just gets sent out. If there's an error, then it has nothing to do with
the clavia.

If you're brave, please write me a PM. I'm currently working on a simple
tool, but it requires Qt4 (binary packages as well as devel packages).
Would be cool to see if it already can do something useful for you.

Best regards

ce
Received on Tue Apr 18 00:15:02 2006

This archive was generated by hypermail 2.1.8 : Tue Apr 18 2006 - 00:15:02 EEST