Re: [LAU] normalize from command line

From: Peder Hedlund <peder@email-addr-hidden>
Date: Fri Aug 26 2011 - 16:36:05 EEST

Quoting Renato <rennabh@email-addr-hidden>:

> On Wed, 24 Aug 2011 17:21:50 -0700
> Ken Restivo <ken@email-addr-hidden> wrote:

>> for i in `ls *wav`; do
>> FOO=`sox $i -e stat -v 2>&1`
>> BN=`basename $i .wav`
>> echo "norming $i with factor $FOO ..."
>> sox -v $FOO $i -t wav ${BN}.norm.wav
>> done
>>
>
> mmh, getting this error:
>
> norming scrivania_varie.wav with factor sox FAIL sox: --encoding:
> `stat' is not one of: signed-integer, unsigned-integer,
> floating-point, ms-adpcm, ima-adpcm, oki-adpcm, gsm-full-rate,
> u-law, mu-law, a-law. ...
> sox FAIL sox: Volume value `sox' is not a number

Try changing the -e to -n on the FOO line.
I guess they replaced "empty" with "null".

  - Peder
_______________________________________________
Linux-audio-user mailing list
Linux-audio-user@email-addr-hidden
http://lists.linuxaudio.org/listinfo/linux-audio-user
Received on Fri Aug 26 20:15:02 2011

This archive was generated by hypermail 2.1.8 : Fri Aug 26 2011 - 20:15:02 EEST