On Tue, 3 Nov 2020, Christopher Arndt wrote:
> I made some tests and it seems that there is indeed a limit of 112 bytes
> for outgoing sysex data.
I knew there was a limit but had never run into it. I realize that the
longest sysex I had used were ~20 bytes (mackie control with LCD info sent
channel at a time)
The one question I do have is the buffer size (128/2 ?) and if you tested
at more than one buffer size. I would expect that the two would be tied
together. I also remember reading that there had been code developed for
jack (I do not remember if it was jack 1 or 2 specific) to allow long,
non-realtime sysex to be used. However, I do not remember if it was ever
included or how it was accessed.
-- Len Ovens www.ovenwerks.net _______________________________________________ Linux-audio-user mailing list Linux-audio-user@lists.linuxaudio.org https://lists.linuxaudio.org/listinfo/linux-audio-userReceived on Wed Nov 4 04:15:01 2020