Re: [linux-audio-dev] +momentary, consolidated (ladspa.h.diff)

New Message Reply About this list Date view Thread view Subject view Author view Other groups

Subject: Re: [linux-audio-dev] +momentary, consolidated (ladspa.h.diff)
From: Matthias Nagorni (mana_AT_suse.de)
Date: Mon Mar 08 2004 - 18:14:12 EET


On Mon, 8 Mar 2004, Taybin Rutkin wrote:

> The presence of both MOMENTARY and TRIGGER seems redundent. TRIGGER means that it's reset to 0 after one call to run() or run_adding()? That'll happen so fast, the user won't even notice the UI change. If TRIGGER is for scale values, how will it scale if it's set to 0 after every call? The distinction between them is overlapping and confusing.

It looks like TRIGGER is for input and MOMENTARY for output ports.

Matthias

-- 
Dr. Matthias Nagorni
SuSE Linux AG
Maxfeldstr. 5             phone: +49 911 74053375
D - 90409 Nuernberg       fax  : +49 911 74053483


New Message Reply About this list Date view Thread view Subject view Author view Other groups

This archive was generated by hypermail 2b28 : Mon Mar 08 2004 - 18:13:42 EET